Mechanical values and environment | |
---|---|
Dimensions | 108 x 22.5 x 114.5 Including screw terminals |
Material | |
Housing | Polyamide |
Ambient temperature | -10 ... +55 °C |
Atmospheric humidity | 10 ... 95 % rH |
Degree of protection | IP20 |
Mounting method | Mounting rail 35mm Acc. to EN 60715 |
Connection | Plug-in screw terminal Terminals not included |
Cable length | max.100 m With length above 50m use cross-section >1mm2. |
Pulse output 1...4 | |
Number of outputs | 4 |
For node selection | |
Number of inputs | 2 |
Safety input 1...16 | |
Number of inputs | 16 |
Electrical connection ratings | |
Operating voltage DC | |
UB | 24 V DC -20% ... +20% PELV Acc. to EN 60204-1 |
Overvoltage category according to IEC EN 60664-1 | II |
Degree of contamination according to EN 60664-1 | 2 |
Connection cross-section | 0,5 ... 2,5 mm? Screw terminal |
Delay time | 0,0106 ... 0,0546 s Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions and calculated values in the software "Euchner Safety Designer") |
Power consumption | max.3 W |
Pulse output 1...4 | |
Test pulses | 0,2 ms |
Type of output | Semiconductor outputs, p-switching Acc. to EN 61131-2 |
For node selection | |
Type of input | Semiconductor inputs, p-switching "Typ2" acc. to EN 61131-2 |
Safety input 1...16 | |
Type of input | Semiconductor inputs, p-switching Acc. to EN 61131-2 |
Reliability values acc. to EN ISO 13849-1 | |
ESPE type | 4 Acc. to EN 61496-1 |
Performance Level | PL e Acc. to ISO 13849-1:2006/IEC 62061:2005 |
Category | 4 Acc. to ISO 13849-1:2006/IEC 62061:2005 |
PFHD | 4.94 E-09 1/h Acc. to IEC 61508:2010 |
SIL CL | 3 Acc. to IEC 62061:2005 |
Mission time | 20 y Acc. to ISO 13849-1:2006/IEC 62061:2005 |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |